Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Radiat Res ; 65(1): 36-46, 2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-37981331

RESUMO

For correct assessment of health risks after low-dose irradiation, calculation of radiation exposure estimates is crucial. To verify the calculated absorbed doses, instrumental methods of retrospective dosimetry are used. We compared calculated and instrumental-based estimates of external absorbed doses in the residents of Dolon, Mostik and Cheremushki villages, Kazakhstan, affected by the first nuclear weapon test performed at the Semipalatinsk Nuclear Test Site (SNTS) on August 29, 1949. The 'instrumental' doses were retrospectively estimated using the Luminescence Retrospective Dosimetry (LRD) and Electron Spin Resonance (ESR) methods. Correlation between the calculated individual cumulative external absorbed whole-body doses based on typical input data and ESR-based individual doses in the same people was strong (r = 0.782). It was even stronger between the calculated doses based on individual questionnaires' input data and the ESR-based doses (r = 0.940). Application of the LRD method is useful for validation of the calculated settlement-average cumulated external absorbed dose to air. Reconstruction of external exposure can be supplemented with the data from later measurements of soil contamination with long-lived radionuclides, such as, 137Cs. Our results show the reliability of the calculational method used for the retrospective assessment of individual external doses.


Assuntos
Guerra Nuclear , Monitoramento de Radiação , Cinza Radioativa , Humanos , Doses de Radiação , Radioisótopos de Césio/análise , Estudos Retrospectivos , Cazaquistão , Monitoramento de Radiação/métodos , Cinza Radioativa/análise , Reprodutibilidade dos Testes
2.
Molecules ; 26(21)2021 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-34770780

RESUMO

Today, 44Sc is an attractive radionuclide for molecular imaging with PET. In this work, we evaluated a 44Ti/44Sc radionuclide generator based on TEVA resin as a source of 44Sc. The generator prototype (5 MBq) exhibits high 44Ti retention and stable yield of 44Sc (91 ± 6 %) in 1 mL of eluate (20 bed volumes, eluent-0.1 M oxalic acid/0.2 M HCl) during one year of monitoring (more than 120 elutions). The breakthrough of 44Ti did not exceed 1.5 × 10-5% (average value was 6.5 × 10-6%). Post-processing of the eluate for further use in radiopharmaceutical synthesis was proposed. The post-processing procedure using a combination of Presep® PolyChelate and TK221 resins made it possible to obtain 44Sc-radioconjugates with high labeling yield (≥95%) while using small precursor amounts (5 nmol). The proposed method takes no more than 15 min and provides ≥90% yield relative to the 44Sc activity eluted from the generator. The labeling efficiency was demonstrated on the example of [44Sc]Sc-PSMA-617 and [44Sc]Sc-PSMA-I&T synthesis. Some superiority of PSMA-I&T over PSMA-617 in terms of 44Sc labeling efficiency was demonstrated (likely due to presence of DOTAGA chelator in the precursor structure). It was also shown that microwave heating of the reaction mixture considerably shortened the reaction time and improved radiolabeling yield and reproducibility of [44Sc]Sc-PSMA-617 and [44Sc]Sc-PSMA-I&T synthesis.


Assuntos
Dipeptídeos/química , Compostos Heterocíclicos com 1 Anel/química , Antígeno Prostático Específico/química , Compostos Radiofarmacêuticos/química , Escândio/isolamento & purificação , Titânio/isolamento & purificação , Quelantes/química , Fracionamento Químico , Técnicas de Química Sintética , Cromatografia , Marcação por Isótopo/métodos , Cinética , Radioisótopos/química , Compostos Radiofarmacêuticos/síntese química , Resinas Sintéticas/química , Escândio/química , Titânio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...